Files
SplitBit-Emulator/Tests/expected/cosmosMonitor.out
T
AnachronautandClaude Opus 5 16f8232a35 Lines that are only run sometimes
if, else, end, and same.

IF TAKES A COMMAND, which is one rule rather than two and is why comparing
values needs no syntax of its own: "same" is an ordinary command that fails when
its two words differ, so "if same $a $b" falls out of the rule instead of being
an exception to it. Anything else that can fail is a question too - "if load
Snake.sbx" is a perfectly good one.

The shell already had the other half. LineFailed exists because a script stops at
the first line that did not work, so every command was already saying whether it
had, for a different reason entirely.

A BLOCK HAS TWO KINDS OF NOT-RUNNING. One where an else would turn it on, and
one where it would not - which is what an if pushes when something above it is
already being skipped. That is what makes nesting need no looking down the
stack: the top of it says everything.

A branch nobody is taking is not even looked at. The skipping happens BEFORE the
names are filled in, so a variable mentioned in a branch that is not running is
not an error - a line nobody runs must not be able to fail.

AND LINES MAY BE INDENTED, which they could not be before there was anything to
indent inside. Nobody writes an if inside an if without indenting what is in
them, and a leading space used to make the first word empty and match nothing.
Found by writing the test script the way anybody would write one.

CALL commandFailed became BRI commandFailed in nine places. It never returns - it
marks the line and branches to the prompt - so calling it was a lie that cost a
Stack frame each time, and fourteen other sites already branched. THE LINT RULE
FOUND THIS, three days after I wrote the rule and on my own code: two false
positives that were really the linter being right about a CALL that is not one.
It does not fix the leak on its own, since a failure inside any called routine
still abandons that frame, but it removes the cause of the commonest case and
makes the code true.

The mechanical edit then left a BRI prompt stranded behind one of them, and the
linter caught that too.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01E2JrLzFvuFX9fgi1LDRjrW
2026-09-01 20:33:33 -04:00

127 lines
3.1 KiB
Plaintext

CosmOS
> monitor
x examine, d disassemble, a assemble, s set, b bank, g go, exit leaves
* b nonsense
b <program|data|number>
* b 9
there is no such bank
* load greet.sbx
loaded, starting at 5000
* b program
bank 00
* d 5000
5000 47 00 30 00 SETD.0 3000
5004 72 10 SWI 10
5006 47 00 30 44 SETD.0 3044
500A 72 10 SWI 10
500C 47 00 30 7A SETD.0 307A
5010 27 1F INIB 1F
5012 72 11 SWI 11
5014 47 00 30 5D SETD.0 305D
* x 5000
5000 47 00 30 00 72 10 47 00 30 44 72 10 47 00 30 7A G.0.r.G.0Dr.G.0z
5010 27 1F 72 11 47 00 30 5D 72 10 47 00 30 7A 72 10 '.r.G.0]r.G.0zr.
5020 47 00 30 65 72 10 20 72 12 00 00 00 00 00 00 00 G.0er. r........
5030 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
* b data
bank 01
* x 3000
3000 61 20 70 72 6F 67 72 61 6D 2C 20 6C 6F 61 64 65 a program, loade
3010 64 20 6F 66 66 20 61 20 64 69 73 6B 2C 20 72 75 d off a disk, ru
3020 6E 6E 69 6E 67 20 6F 6E 20 74 68 65 20 73 79 73 nning on the sys
3030 74 65 6D 20 74 68 61 74 20 6C 6F 61 64 65 64 20 tem that loaded
* b 2
bank 02
* x 0
0000 01 FF 00 00 00 00 00 00 01 FF 00 00 00 00 00 00 ................
0010 03 FF 08 00 00 00 00 00 01 20 01 00 00 00 00 00 ......... ......
0020 00 FF 00 00 00 00 00 00 00 FF 00 00 00 00 00 00 ................
0030 00 FF 00 00 00 00 00 00 00 FF 00 00 00 00 00 00 ................
* s 0 FF
that bank will not be written
* b program
bank 00
* s 8000 26 48 D1 00 26 0A D1 00 18 12
* d 8000
8000 26 48 INIA 48
8002 D1 00 OUTA 00
8004 26 0A INIA 0A
8006 D1 00 OUTA 00
8008 18 SHR
8009 12 AND
800A 00 ?
800B 00 ?
* g 8000
H
that byte is not an instruction, at 800A
A 85 B 3F Q 05
the program was stopped
* d 8000
8000 26 48 INIA 48
8002 D1 00 OUTA 00
8004 26 0A INIA 0A
8006 D1 00 OUTA 00
8008 18 SHR
8009 12 AND
800A 00 ?
800B 00 ?
* b data
bank 01
* s 8100 68 65 6C 6C 6F 2C 20 74 79 70 65 64 0A 00
* b program
bank 00
* a 8200
8200: SETD.0 8100
8204: SWI 10
8206: lda.2
8208: LDD.0.1
820B: frobnicate
no such instruction
820B: INIA
that one needs a value after it
820B: SWI 12
820D: .
* d 8200
8200 47 00 81 00 SETD.0 8100
8204 72 10 SWI 10
8206 42 02 LDA.2
8208 4A 00 01 LDD.0.1
820B 72 12 SWI 12
820D 00 ?
820E 00 ?
820F 00 ?
* g 8200
hello, typed
finished
* exit
> dir
greet.sbx 211
hello.sbx 53
Life.sbx 1396
Snake.sbx 2164
Keys.sbx 664
Say.sbx 156
Break.sbx 149
Grid.sbx 559
Press.sbx 872
Mode.sbx 48
Crash.sbx 632
vars.script 50
blocks.script 343
tune.sbx 306
notes.txt 21
Apps <dir>
hi.script 121
bad.script 45
plain.script 24
cross.script 280
nonl.script 38
outer.script 376
inner.script 44
loop.script 35
23 files, 1 directory
> exit
halted
Execution halted.
[exit 0]